G62 Date/Time

To specify pertinent dates and times

Position
Element
Name
Type
Requirement
Min
Max
Repeat
G62-01
Date Qualifier
Identifier (ID)
Conditional
2
2
-
Code specifying type of date
R0103: At least one of G62-01 or G62-03 is required
P0102: If either G62-01 or G62-02 is present, then the other is required
G62-02
Date
Date (DT)
Conditional
8
8
-
Date expressed as CCYYMMDD
G62-03
Time Qualifier
Identifier (ID)
Conditional
1
2
-
Code specifying the reported time
P0304: If either G62-03 or G62-04 is present, then the other is required
G62-04
Time
Time (TM)
Conditional
4
8
-
Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99)
G62-05
Time Code
Identifier (ID)
Optional
2
2
-
Code identifying the time. In accordance with International Standards Organization standard 8601, time can be specified by a + or - and an indication in hours in relation to Universal Time Coordinate (UTC) time; since + is a restricted character, + and - are substituted by P and M in the codes that follow

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.