QALITY Quality data
Submitted by WEEB-MD1 on behalf of PAEB
A message to enable the transmission of the results of tests performed to satisfy a specified product or process requirement. The content includes, but is not limited to, test data and measurements, statistical information, and the testing methods employed.
Header
- 0010Message headerMandatoryMax 1
To head, identify and specify a message.
- 0020Beginning of messageMandatoryMax 1
To indicate the type and function of a message and to transmit the identifying number.
- 0030Date/time/periodMandatoryMax 10
To specify date, and/or time, or period.
- 0040Item descriptionConditionalMax 10
To describe an item in either an industry or free format.
- 0050MeasurementsConditionalMax 10
To specify physical measurements, including dimension tolerances, weights and counts.
- 0060Free textConditionalMax 5
To provide free form or coded text information.
- Segment group 1Repeat 10
- 0080ReferenceMandatoryMax 1
To specify a reference.
- 0090Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0080ReferenceMandatoryMax 1
- Segment group 2Repeat 10
- 0110Name and addressMandatoryMax 1
To specify the name/address and their related function, either by CO82 only and/or unstructured by CO58 or structured by CO80 thru 3207.
- 0120Place/location identificationConditionalMax 5
To identify a place or a location and/or related locations.
- Segment group 3Repeat 10
- 0140ReferenceMandatoryMax 1
To specify a reference.
- 0150Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0140ReferenceMandatoryMax 1
- Segment group 4Repeat 5
- 0170Contact informationMandatoryMax 1
To identify a person or a department to whom communication should be directed.
- 0180Communication contactConditionalMax 5
To identify a communication number of a department or a person to whom communication should be directed.
- 0170Contact informationMandatoryMax 1
- 0110Name and addressMandatoryMax 1
Detail
- Segment group 5Repeat 200
- 0200Line itemMandatoryMax 1
To identify a line item and configuration.
- 0210Additional product idConditionalMax 10
To specify additional or substitutional item identification codes.
- 0220Item descriptionConditionalMax 10
To describe an item in either an industry or free format.
- 0230MeasurementsConditionalMax 10
To specify physical measurements, including dimension tolerances, weights and counts.
- 0240Physical sample descriptionConditionalMax 1
To define the physical sample parameters associated with a test, resulting in discrete measurements.
- 0250Sampling parameters for summary statisticsConditionalMax 1
To define the sampling parameters associated with summary statistics reported.
- 0260Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- 0270QuantityConditionalMax 99
To specify a pertinent quantity.
- 0280Free textConditionalMax 5
To provide free form or coded text information.
- Segment group 6Repeat 10
- 0300ReferenceMandatoryMax 1
To specify a reference.
- 0310Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0300ReferenceMandatoryMax 1
- Segment group 7Repeat 10
- 0330Name and addressMandatoryMax 1
To specify the name/address and their related function, either by CO82 only and/or unstructured by CO58 or structured by CO80 thru 3207.
- 0340Place/location identificationConditionalMax 5
To identify a place or a location and/or related locations.
- Segment group 8Repeat 10
- 0360ReferenceMandatoryMax 1
To specify a reference.
- 0370Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0360ReferenceMandatoryMax 1
- Segment group 9Repeat 5
- 0390Contact informationMandatoryMax 1
To identify a person or a department to whom communication should be directed.
- 0400Communication contactConditionalMax 5
To identify a communication number of a department or a person to whom communication should be directed.
- 0390Contact informationMandatoryMax 1
- 0330Name and addressMandatoryMax 1
- Segment group 10Repeat 100
- 0420Test methodMandatoryMax 1
To describe the nature of the test performed.
- 0430MeasurementsConditionalMax 100
To specify physical measurements, including dimension tolerances, weights and counts.
- 0440Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 11Repeat 10
- 0460ReferenceMandatoryMax 1
To specify a reference.
- 0470Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0460ReferenceMandatoryMax 1
- 0420Test methodMandatoryMax 1
- Segment group 12Repeat 200
- 0490Characteristic/class idMandatoryMax 1
To identify and describe a specific characteristic and its relevance for subsequent business processes.
- 0500Physical sample descriptionConditionalMax 10
To define the physical sample parameters associated with a test, resulting in discrete measurements.
- 0510Sampling parameters for summary statisticsConditionalMax 10
To define the sampling parameters associated with summary statistics reported.
- 0520Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- 0530Free textConditionalMax 10
To provide free form or coded text information.
- Segment group 13Repeat 10
- 0550ReferenceMandatoryMax 1
To specify a reference.
- 0560Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0550ReferenceMandatoryMax 1
- Segment group 14Repeat 999
- 0580MeasurementsMandatoryMax 1
To specify physical measurements, including dimension tolerances, weights and counts.
- 0590Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 15Repeat 10
- 0610ReferenceMandatoryMax 1
To specify a reference.
- 0620Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0610ReferenceMandatoryMax 1
- 0580MeasurementsMandatoryMax 1
- Segment group 16Repeat 100
- 0640StatisticsMandatoryMax 1
To transmit summary statistics related to a specified collection of test result values.
- 0650Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 17Repeat 10
- 0670ReferenceMandatoryMax 1
To specify a reference.
- 0680Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0670ReferenceMandatoryMax 1
- 0640StatisticsMandatoryMax 1
- Segment group 18Repeat 100
- 0700Test methodMandatoryMax 1
To describe the nature of the test performed.
- 0710MeasurementsConditionalMax 100
To specify physical measurements, including dimension tolerances, weights and counts.
- 0720Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 19Repeat 10
- 0740ReferenceMandatoryMax 1
To specify a reference.
- 0750Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0740ReferenceMandatoryMax 1
- 0700Test methodMandatoryMax 1
- 0490Characteristic/class idMandatoryMax 1
- Segment group 20Repeat 100
- 0770Goods identity numberMandatoryMax 1
To give specific identification numbers, either as single numbers or ranges.
- 0780Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 21Repeat 10
- 0800ReferenceMandatoryMax 1
To specify a reference.
- 0810Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0800ReferenceMandatoryMax 1
- Segment group 22Repeat 200
- 0830Characteristic/class idMandatoryMax 1
To identify and describe a specific characteristic and its relevance for subsequent business processes.
- 0840Physical sample descriptionConditionalMax 10
To define the physical sample parameters associated with a test, resulting in discrete measurements.
- 0850Sampling parameters for summary statisticsConditionalMax 10
To define the sampling parameters associated with summary statistics reported.
- 0860Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- 0870Free textConditionalMax 10
To provide free form or coded text information.
- Segment group 23Repeat 10
- 0890ReferenceMandatoryMax 1
To specify a reference.
- 0900Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0890ReferenceMandatoryMax 1
- Segment group 24Repeat 999
- 0920MeasurementsMandatoryMax 1
To specify physical measurements, including dimension tolerances, weights and counts.
- 0930Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 25Repeat 10
- 0950ReferenceMandatoryMax 1
To specify a reference.
- 0960Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 0950ReferenceMandatoryMax 1
- 0920MeasurementsMandatoryMax 1
- Segment group 26Repeat 100
- 0980StatisticsMandatoryMax 1
To transmit summary statistics related to a specified collection of test result values.
- 0990Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 27Repeat 10
- 1010ReferenceMandatoryMax 1
To specify a reference.
- 1020Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 1010ReferenceMandatoryMax 1
- 0980StatisticsMandatoryMax 1
- Segment group 28Repeat 100
- 1040Test methodMandatoryMax 1
To describe the nature of the test performed.
- 1050MeasurementsConditionalMax 100
To specify physical measurements, including dimension tolerances, weights and counts.
- 1060Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 29Repeat 10
- 1080ReferenceMandatoryMax 1
To specify a reference.
- 1090Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 1080ReferenceMandatoryMax 1
- 1040Test methodMandatoryMax 1
- 0830Characteristic/class idMandatoryMax 1
- 0770Goods identity numberMandatoryMax 1
- Segment group 30Repeat 100
- 1110Process identificationMandatoryMax 1
To identify a process.
- Segment group 31Repeat 10
- 1130Name and addressMandatoryMax 1
To specify the name/address and their related function, either by CO82 only and/or unstructured by CO58 or structured by CO80 thru 3207.
- 1140Place/location identificationConditionalMax 5
To identify a place or a location and/or related locations.
- 1130Name and addressMandatoryMax 1
- Segment group 32Repeat 200
- 1160Characteristic/class idMandatoryMax 1
To identify and describe a specific characteristic and its relevance for subsequent business processes.
- 1170Physical sample descriptionConditionalMax 10
To define the physical sample parameters associated with a test, resulting in discrete measurements.
- 1180Sampling parameters for summary statisticsConditionalMax 10
To define the sampling parameters associated with summary statistics reported.
- 1190Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- 1200Free textConditionalMax 10
To provide free form or coded text information.
- Segment group 33Repeat 10
- 1220ReferenceMandatoryMax 1
To specify a reference.
- 1230Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 1220ReferenceMandatoryMax 1
- Segment group 34Repeat 999
- 1250MeasurementsMandatoryMax 1
To specify physical measurements, including dimension tolerances, weights and counts.
- 1260Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 35Repeat 10
- 1280ReferenceMandatoryMax 1
To specify a reference.
- 1290Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 1280ReferenceMandatoryMax 1
- 1250MeasurementsMandatoryMax 1
- Segment group 36Repeat 100
- 1310StatisticsMandatoryMax 1
To transmit summary statistics related to a specified collection of test result values.
- 1320Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 37Repeat 10
- 1340ReferenceMandatoryMax 1
To specify a reference.
- 1350Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 1340ReferenceMandatoryMax 1
- 1310StatisticsMandatoryMax 1
- Segment group 38Repeat 100
- 1370Test methodMandatoryMax 1
To describe the nature of the test performed.
- 1380MeasurementsConditionalMax 100
To specify physical measurements, including dimension tolerances, weights and counts.
- 1390Date/time/periodConditionalMax 10
To specify date, and/or time, or period.
- Segment group 39Repeat 10
- 1410ReferenceMandatoryMax 1
To specify a reference.
- 1420Date/time/periodConditionalMax 2
To specify date, and/or time, or period.
- 1410ReferenceMandatoryMax 1
- 1370Test methodMandatoryMax 1
- 1160Characteristic/class idMandatoryMax 1
- 1110Process identificationMandatoryMax 1
- 0200Line itemMandatoryMax 1
- 1430Message trailerMandatoryMax 1
To end and check the completeness of a message.