MEA Measurements

To specify physical measurements or counts, including dimensions, tolerances, variances, and weights (See X12 EDI Standard Figures, https://figures.x12.org, for example of use of C001)

Position
Element
Name
Type
Requirement
Min
Max
Repeat
MEA-01
Measurement Reference ID Code
Identifier (ID)
Optional
2
2
1
Code identifying the broad category to which a measurement applies
MEA-02
Measurement Qualifier
Identifier (ID)
Optional
1
3
1
Code identifying a specific product or process characteristic to which a measurement applies
MEA-03
Measurement Value
Decimal number (R)
Conditional
1
20
1
The value of the measurement
R03050608: At least one of MEA-03, MEA-05, MEA-06 or MEA-08 is required
MEA-04
Composite Unit of Measure
Composite (composite)
Conditional
1
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
MEA-05
Range Minimum
Decimal number (R)
Conditional
1
20
1
The value specifying the minimum of the measurement range
L050412: If MEA-05 is present, then at least one of MEA-04 or MEA-12 is required
When citing dimensional tolerances, any measurement requiring a sign (+ or -), or any measurement where a positive (+) value cannot be assumed, use MEA05 as the negative (-) value and MEA06 as the positive (+) value.
MEA-06
Range Maximum
Decimal number (R)
Conditional
1
20
1
The value specifying the maximum of the measurement range
L060412: If MEA-06 is present, then at least one of MEA-04 or MEA-12 is required
MEA-07
Measurement Significance Code
Identifier (ID)
Optional
2
2
1
Code indicating the benchmark of, qualify or further define a measurement value
L07030506: If MEA-07 is present, then at least one of MEA-03, MEA-05 or MEA-06 is required
MEA-08
Measurement Attribute Code
Identifier (ID)
Conditional
2
2
1
Code indicating an attribute response when a numeric measurement value cannot be determined
E0803: Only one of MEA-08 or MEA-03 may be present
MEA-09
Surface/Layer/Position Code
Identifier (ID)
Optional
2
2
1
Code indicating the product surface, layer or position that is being described
MEA-10
Measurement Method or Device Code
Identifier (ID)
Optional
2
4
1
Code indicating the method or device used to record the measurement
MEA-11
Code List Qualifier Code
Identifier (ID)
Conditional
1
3
1
Code identifying a specific industry code list
P1112: If either MEA-11 or MEA-12 is present, then the other is required
MEA11 is the external code list for the unit of measure.
MEA-12
Industry Code
String (AN)
Conditional
1
30
1
Code indicating a code from a specific industry code list
MEA12 defines the unit of measure for MEA03, MEA05, and MEA06 from an external code list.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.