AT7 Shipment Status Details

To specify the status of a shipment, the reason for that status, the date and time of the status and the date and time of any appointments scheduled.

Position
Element
Name
Type
Requirement
Min
Max
Repeat
AT7-01
Shipment Status Code
Identifier (ID)
Conditional
2
2
1
Code indicating the status of a shipment
E0103: Only one of AT7-01 or AT7-03 may be present
If AT701 is present, AT705 is the date the status occurred. If AT703 is present, AT705 is a date related to an appointment.
If AT701 is present, AT706 is the time of the status. If AT703 is present, AT706 is the time of the appointment.
AT7-02
Shipment Status or Appointment Reason Code
Identifier (ID)
Optional
2
2
1
Code indicating the reason a shipment status or appointment reason was transmitted
C0201: If AT7-02 is present, then AT7-01 is required
AT7-03
Shipment Appointment Status Code
Identifier (ID)
Conditional
2
2
1
Code indicating the status of an appointment to pick-up or deliver a shipment
AT7-04
Shipment Status or Appointment Reason Code
Identifier (ID)
Optional
2
2
1
Code indicating the reason a shipment status or appointment reason was transmitted
C0403: If AT7-04 is present, then AT7-03 is required
AT7-05
Date
Date (DT)
Conditional
8
8
1
Date expressed as CCYYMMDD where CC represents the first two digits of the calendar year
AT7-06
Time
Time (TM)
Conditional
4
8
1
Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99)
C0605: If AT7-06 is present, then AT7-05 is required
AT7-07
Time Code
Identifier (ID)
Optional
2
2
1
Code identifying the time. In accordance with International Standards Organization standard 8601, time can be specified by a + or - and an indication in hours in relation to Universal Time Coordinate (UTC) time; since + is a restricted character, + and - are substituted by P and M in the codes that follow
C0706: If AT7-07 is present, then AT7-06 is required
If AT707 is not present then AT706 represents local time of the status.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.