American Association of Railroads (AAR)
/
Rail Advance Interchange Consist (7050)
  • Specification
  • EDI Inspector
Stedi maintains this guide based on public documentation from American Association of Railroads (AAR). Contact American Association of Railroads (AAR) for official EDI specifications. To report any errors in this guide, please contact us.
Go to Stedi Network
American Association of Railroads (AAR) logo

X12 418 Rail Advance Interchange Consist (7050)

X12 Release 7050
Delimiters
  • ~ Segment
  • * Element
  • > Component
  • ^ Repetition
EDI sample
  • Sample 1
View the latest version of this implementation guide as an interactive webpage
https://www.stedi.com/app/guides/view/aar/rail-advance-interchange-consist-7050/01HK5X7C5ZM9GXXG98BDS71Q8P
Powered by
Build EDI implementation guides at stedi.com
Overview
ISA
-
Interchange Control Header
Max use 1
Required
GS
-
Functional Group Header
Max use 1
Required
heading
ST
0100
Transaction Set Header
Max use 1
Required
BAX
0200
Beginning Segment for Advance Consist and Transportation Automatic Equipment ID
Max use 1
Required
W1 Loop
W1
0300
Block Identification
Max use 1
Required
W2 Loop
W2
0400
Equipment Identification
Max use 1
Required
W3
0500
Consignee Information
Max use 7
Optional
IMA
0600
Interchange Move Authority
Max use 3
Optional
W4
0700
Consignor Information
Max use 1
Optional
W5
0800
Carrier and Route Information
Max use 4
Optional
W6
0900
Special Handling Information
Max use 6
Optional
REF
1100
Reference Information
Max use 10
Optional
LS
1200
Loop Header
Max use 1
Optional
LH1 Loop
LE
2100
Loop Trailer
Max use 1
Optional
SE
2500
Transaction Set Trailer
Max use 1
Required
GE
-
Functional Group Trailer
Max use 1
Required
IEA
-
Interchange Control Trailer
Max use 1
Required
ISA

Interchange Control Header

RequiredMax use 1
Example
ISA-01
I01
Authorization Information Qualifier
Required
Identifier (ID)
00
No Authorization Information Present (No Meaningful Information in I02)
ISA-02
I02
Authorization Information
Required
String (AN)
Min 10Max 10
ISA-03
I03
Security Information Qualifier
Required
Identifier (ID)
00
No Security Information Present (No Meaningful Information in I04)
ISA-04
I04
Security Information
Required
String (AN)
Min 10Max 10
ISA-05
I05
Interchange ID Qualifier
Required
Identifier (ID)
Min 2Max 2
Codes
ISA-06
I06
Interchange Sender ID
Required
String (AN)
Min 15Max 15
ISA-07
I05
Interchange ID Qualifier
Required
Identifier (ID)
Min 2Max 2
Codes
ISA-08
I07
Interchange Receiver ID
Required
String (AN)
Min 15Max 15
ISA-09
I08
Interchange Date
Required
Date (DT)
YYMMDD format
ISA-10
I09
Interchange Time
Required
Time (TM)
HHMM format
ISA-11
I65
Repetition Separator
Required
String (AN)
Min 1Max 1
^
Repetition Separator
ISA-12
I11
Interchange Control Version Number Code
Required
Identifier (ID)
00705
Standards Approved for Publication by ASC X12 Procedures Review Board through December 2017
ISA-13
I12
Interchange Control Number
Required
Numeric (N0)
Min 9Max 9
ISA-14
I13
Acknowledgment Requested Code
Required
Identifier (ID)
Min 1Max 1
0
No Interchange Acknowledgment Requested
1
Interchange Acknowledgment Requested (TA1)
2
Interchange Acknowledgment Requested only when Interchange is "Rejected Because Of Errors"
3
Interchange Acknowledgment Requested only when Interchange is "Rejected Because Of Errors" or "Accepted but Errors are Noted"
ISA-15
I14
Interchange Usage Indicator Code
Required
Identifier (ID)
Min 1Max 1
I
Information
P
Production Data
T
Test Data
ISA-16
I15
Component Element Separator
Required
String (AN)
Min 1Max 1
>
Component Element Separator

Functional Group Header

RequiredMax use 1
Example
GS-01
479
Functional Identifier Code
Required
Identifier (ID)
IC
Rail Advance Interchange Consist (418)
GS-02
142
Application Sender's Code
Required
String (AN)
Min 2Max 15
GS-03
124
Application Receiver's Code
Required
String (AN)
Min 2Max 15
Required
Date (DT)
CCYYMMDD format
Required
Time (TM)
HHMM, HHMMSS, HHMMSSD, or HHMMSSDD format
GS-06
28
Group Control Number
Required
Numeric (N0)
Min 1Max 9
GS-07
455
Responsible Agency Code
Required
Identifier (ID)
Min 1Max 2
T
Transportation Data Coordinating Committee (TDCC)
X
Accredited Standards Committee X12
GS-08
480
Version / Release / Industry Identifier Code
Required
String (AN)
007050
Standards Approved for Publication by ASC X12 Procedures Review Board through December 2017

Heading

ST
0100
Heading > ST

Transaction Set Header

RequiredMax use 1
Example
ST-01
143
Transaction Set Identifier Code
Required
Identifier (ID)
418
Rail Advance Interchange Consist
ST-02
329
Transaction Set Control Number
Required
Numeric (N)
Min 4Max 9
BAX
0200
Heading > BAX

Beginning Segment for Advance Consist and Transportation Automatic Equipment ID

RequiredMax use 1
Example
BAX-01
154
Standard Point Location Code
Required
Identifier (ID)
Min 6Max 9
BAX-02
579
Type of Consist Code
Required
Identifier (ID)
J
Joint Track
BAX-03
374
Date/Time Qualifier
Required
Identifier (ID)
139
Estimated
140
Actual
Required
Date (DT)
CCYYMMDD format
Required
Time (TM)
HHMM, HHMMSS, HHMMSSD, or HHMMSSDD format
BAX-06
41
Interchange Train Identification
Required
String (AN)
Min 1Max 10
BAX-07
154
Standard Point Location Code
Required
Identifier (ID)
Min 6Max 9
BAX-08
127
Reference Identification
Optional
String (AN)
Min 1Max 80
Required
Date (DT)
CCYYMMDD format
BAX-14
284
Service Level Code
Optional
Identifier (ID)
Min 2Max 2
W1 Loop
RequiredMax >1
W1
0300
Heading > W1 Loop > W1

Block Identification

RequiredMax use 1
Example
W1-01
42
Block Identifier
Required
String (AN)
Min 1Max 12
W2 Loop
RequiredMax >1
W2
0400
Heading > W1 Loop > W2 Loop > W2

Equipment Identification

RequiredMax use 1
Example
W2-01
206
Equipment Initial
Required
String (AN)
Min 1Max 4
W2-02
207
Equipment Number
Required
String (AN)
Min 1Max 15
W2-03
22
Commodity Code
Optional
String (AN)
Min 1Max 30
W2-04
40
Equipment Description Code
Required
Identifier (ID)
Min 2Max 2
W2-05
578
Equipment Status Code
Required
Identifier (ID)
Min 1Max 2
W2-06
577
Net Tons
Optional
Numeric (N0)
Min 1Max 4
W2-13
761
Equipment Number Check Digit
Optional
Numeric (N0)
Min 1Max 1
W2-14
219
Position
Optional
String (AN)
Min 1Max 3
W2-15
301
Car Type Code
Optional
Identifier (ID)
Min 1Max 4
W3
0500
Heading > W1 Loop > W2 Loop > W3

Consignee Information

OptionalMax use 7
Example
If either Waybill Number (W3-01) or Date (W3-02) is present, then the other is required
If either City Name (W3-04) or State or Province Code (W3-05) is present, then the other is required
W3-01
186
Waybill Number
Optional
Numeric (N0)
Min 1Max 6
Optional
Date (DT)
CCYYMMDD format
W3-03
576
Abbreviated Customer Name
Optional
String (AN)
Min 2Max 12
W3-04
19
City Name
Optional
String (AN)
Min 2Max 30
W3-05
156
State or Province Code
Optional
Identifier (ID)
Min 2Max 2
IMA
0600
Heading > W1 Loop > W2 Loop > IMA

Interchange Move Authority

OptionalMax use 3
Example
IMA-01
748
Movement Authority Code
Required
Identifier (ID)
Min 1Max 2
IMA-02
140
Standard Carrier Alpha Code
Optional
Identifier (ID)
Min 2Max 4
IMA-03
257
Tariff Application Code
Optional
Identifier (ID)
D
Reciprocal
E
Intraterminal
F
Interterminal
IMA-04
257
Tariff Application Code
Optional
Identifier (ID)
N
Interstate
S
Intrastate
IMA-05
901
Reject Reason Code
Optional
Identifier (ID)
Min 2Max 2
W4
0700
Heading > W1 Loop > W2 Loop > W4

Consignor Information

OptionalMax use 1
Example
If either Standard Carrier Alpha Code (W4-02) or Freight Station Accounting Code (W4-03) is present, then the other is required
If either City Name (W4-04) or State or Province Code (W4-05) is present, then the other is required
At least one of Standard Carrier Alpha Code (W4-02) or City Name (W4-04) is required
W4-01
576
Abbreviated Customer Name
Optional
String (AN)
Min 2Max 12
W4-02
140
Standard Carrier Alpha Code
Optional
Identifier (ID)
Min 2Max 4
W4-03
573
Freight Station Accounting Code
Optional
Identifier (ID)
Min 1Max 5
W4-04
19
City Name
Optional
String (AN)
Min 2Max 30
W4-05
156
State or Province Code
Optional
Identifier (ID)
Min 2Max 2
W5
0800
Heading > W1 Loop > W2 Loop > W5

Carrier and Route Information

OptionalMax use 4
Example
W5-01
140
Standard Carrier Alpha Code
Required
Identifier (ID)
Min 2Max 4
W5-02
19
City Name
Optional
String (AN)
Min 2Max 30
W5-03
140
Standard Carrier Alpha Code
Optional
Identifier (ID)
Min 2Max 4
W5-04
19
City Name
Optional
String (AN)
Min 2Max 30
W5-05
140
Standard Carrier Alpha Code
Optional
Identifier (ID)
Min 2Max 6
W5-06
19
City Name
Optional
String (AN)
Min 2Max 30
W6
0900
Heading > W1 Loop > W2 Loop > W6

Special Handling Information

OptionalMax use 6
Example
W6-01
152
Special Handling Code
Required
Identifier (ID)
Min 2Max 3
W6-02
152
Special Handling Code
Optional
Identifier (ID)
Min 2Max 3
W6-03
152
Special Handling Code
Optional
Identifier (ID)
Min 2Max 3
W6-04
152
Special Handling Code
Optional
Identifier (ID)
Min 2Max 3
REF
1100
Heading > W1 Loop > W2 Loop > REF

Reference Information

OptionalMax use 10
Example
At least one of Reference Identification (REF-02) or Description (REF-03) is required
REF-01
128
Reference Identification Qualifier
Required
Identifier (ID)
Min 2Max 3
REF-02
127
Reference Identification
Optional
String (AN)
Min 1Max 80
REF-03
352
Description
Optional
String (AN)
Min 1Max 80
LS
1200
Heading > W1 Loop > W2 Loop > LS

Loop Header

OptionalMax use 1
Example
LS-01
447
Loop Identifier Code
Required
String (AN)
Min 1Max 6
LH1 Loop
OptionalMax >1
LH1
1300
Heading > W1 Loop > W2 Loop > LH1 Loop > LH1

Hazardous Identification Information

RequiredMax use 1
Example
If either Unit or Basis for Measurement Code (LH1-06) or Quantity (LH1-07) is present, then the other is required
LH1-01
355
Unit or Basis for Measurement Code
Required
Identifier (ID)
Min 2Max 2
LH1-02
80
Lading Quantity
Required
Numeric (N0)
Min 1Max 7
LH1-03
277
UN/NA Identification Code
Optional
Identifier (ID)
Min 6Max 6
LH1-05
22
Commodity Code
Optional
String (AN)
Min 1Max 30
LH1-06
355
Unit or Basis for Measurement Code
Optional
Identifier (ID)
Min 2Max 2
LH1-07
380
Quantity
Optional
Decimal number (R)
Min 1Max 15
LH1-10
254
Packing Group Code
Optional
Identifier (ID)
Min 1Max 3
LH2
1400
Heading > W1 Loop > W2 Loop > LH1 Loop > LH2

Hazardous Classification Information

OptionalMax use 4
Example
LH2-01
215
Hazardous Classification Code
Optional
Identifier (ID)
Min 1Max 30
LH2-02
983
Hazardous Class Qualifier
Optional
Identifier (ID)
Min 1Max 1
LH2-03
218
Hazardous Placard Notation Code
Optional
Identifier (ID)
Min 14Max 40
LH2-04
222
Hazardous Endorsement Code
Optional
Identifier (ID)
Min 4Max 25
LH3
1500
Heading > W1 Loop > W2 Loop > LH1 Loop > LH3

Hazardous Material Shipping Name Information

OptionalMax use 10
Example
If either Hazardous Material Shipping Name (LH3-01) or Hazardous Material Shipping Name Qualifier (LH3-02) is present, then the other is required
LH3-01
224
Hazardous Material Shipping Name
Optional
String (AN)
Min 1Max 25
LH3-02
984
Hazardous Material Shipping Name Qualifier
Optional
Identifier (ID)
Min 1Max 1
LFH
1600
Heading > W1 Loop > W2 Loop > LH1 Loop > LFH

Free-form Hazardous Material Information

OptionalMax use 20
Example
LFH-01
808
Hazardous Material Shipment Information Qualifier
Required
Identifier (ID)
Min 3Max 3
LFH-02
809
Hazardous Material Shipment Information
Required
String (AN)
Min 1Max 25
PER
2050
Heading > W1 Loop > W2 Loop > LH1 Loop > PER

Administrative Communications Contact

OptionalMax use 5
Example
If either Communication Number Qualifier (PER-03) or Communication Number (PER-04) is present, then the other is required
PER-01
366
Contact Function Code
Required
Identifier (ID)
Min 2Max 2
Optional
String (AN)
Min 1Max 60
PER-03
365
Communication Number Qualifier
Optional
Identifier (ID)
Min 2Max 2
PER-04
364
Communication Number
Optional
String (AN)
Min 1Max 2048
LH1 Loop end
LE
2100
Heading > W1 Loop > W2 Loop > LE

Loop Trailer

OptionalMax use 1
Example
LE-01
447
Loop Identifier Code
Required
String (AN)
Min 1Max 6
W2 Loop end
W1 Loop end
SE
2500
Heading > SE

Transaction Set Trailer

RequiredMax use 1
Example
SE-01
96
Number of Included Segments
Required
Numeric (N0)
Min 1Max 10
SE-02
329
Transaction Set Control Number
Required
Numeric (N)
Min 4Max 9
Heading end

Functional Group Trailer

RequiredMax use 1
Example
GE-01
97
Number of Transaction Sets Included
Required
Numeric (N0)
Min 1Max 6
GE-02
28
Group Control Number
Required
Numeric (N0)
Min 1Max 9

Interchange Control Trailer

RequiredMax use 1
Example
IEA-01
I16
Number of Included Functional Groups
Required
Numeric (N0)
Min 1Max 5
IEA-02
I12
Interchange Control Number
Required
Numeric (N0)
Min 9Max 9
EDI Samples

Sample 1

ISA*00* *00* *02*UP *02*BNSF *200803*0012*U*00401*975964991*0*P*>
GS*IC*UP*BNSF*20200803*0012*000001080*X*007050
ST*418*10800001
BAX*875640*J*139*20200803*0012*YST62 02*875640********FYST60103 *1
W1*ENG
W2*UP*8999**LO*O*2140.
W2*UP*7243**LO*O*208
W2*UP*7840**LO*O*210
W2*UP*7849**LO*O*210
W1*STKN
W2*DTTX*467437*9999999*SK*L*9*********S615
W3*999999*20200728*UPTRACKAGE*SEATTLE*WA
W4*UPTRACKAGE*UP*6707*GILLIAM*OR
W5*UP
W6*NH
W2*SEGU*159071*4950130*CN*L*7*******8*DB1*U221
W3*300530*20200722*YANGMINAMERI*WEST BASIN*CA
IMA*HM*BNSF
W4*YANGMINAMERI*BNSF*65495*CLINTON*SC
W5*BNSF*SOUGA*BNSF*WCOLT*BNSFW6*XP
REF*BN*YHU657349
REF*WU*YM UNICORN
REF*V3*047W
LS*0800
LH1*BX*216*UN3287**4925249*LB*8699***III
LH2*6.1*P*PLACARDED POISON*DANGEROUS
LH3*TOXIC LIQUID, INORGANIC,*I
LH3*N.O.S.*I
LFH*TEC*(POTASSIUM DICHROMATE)
LE*0800
PER*HM*CHEMTREC CCN5324*TE*17035273887
W1*STKN
W2*TTZX*865698*2421184*RR*E**********F483
W3*999999*20200801*UPTRACKAGE*WILLAMINA*OR
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*EUGEN*PNWR
W2*TTZX*865015*2421184*RR*E**********F483
W3*999999*20200801*UPTRACKAGE*EUGENE*OR
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*EUGEN*PNWR*EUGEN*BNSF
W1*CCT
W2*HRTX*57141*2083110*RR*L*86*********C114
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*4060*POCATELLO*ID
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*BRGX*447*4912186*RR*L*96*********T109
W3*594035*20200724*CONTANTERLLC*STOCKTON*CA
W4*REGMARLOGGRO*UP*1156*SINCLAIR*WY
W5*UP*PSTKN*BNSF*PSTKN*CCT
LS*110
LH1*C4*1*UN1202**4912186*****III
LH2*3*P
LH3*DIESEL FUEL*D
LFH*TEC*(RENEWABLE HYDROCARBON DI*ESEL)
LE*110
PER*HM*CHEMTREC-710399*TE*8004249300
W2*BRGX*948*4912186*RR*L*95*********T109
W3*594037*20200724*CONTANTERLLC*STOCKTON*CA
W4*REGMARLOGGRO*UP*1156*SINCLAIR*WY
W5*UP*PSTKN*BNSF*PSTKN*CCT
LS*110
LH1*C4*1*UN1202**4912186*****III
LH2*3*P
LH3*DIESEL FUEL*D
LFH*TEC*(RENEWABLE HYDROCARBON DI*ESEL)
LE*110
PER*HM*CHEMTREC-710399*TE*8004249300
W2*BRGX*264*4912186*RR*L*95*********T109
W3*594034*20200724*CONTANTERLLC*STOCKTON*CA
W4*REGMARLOGGRO*UP*1156*SINCLAIR*WY
W5*UP*PSTKN*BNSF*PSTKN*CCT
LS*110
LH1*C4*1*UN1202**4912186*****III
LH2*3*P
LH3*DIESEL FUEL*D
LFH*TEC*(RENEWABLE HYDROCARBON DI*ESEL)
LE*110
PER*HM*CHEMTREC-710399*TE*8004249300
W2*BRGX*863*4912186*RR*L*95*********T109
W3*594038*20200724*CONTANTERLLC*STOCKTON*CA
W4*REGMARLOGGRO*UP*1156*SINCLAIR*WY
W5*UP*PSTKN*BNSF*PSTKN*CCT
LS*110
LH1*C4*1*UN1202**4912186*****III
LH2*3*P
LH3*DIESEL FUEL*D
LFH*TEC*(RENEWABLE HYDROCARBON DI*ESEL)
LE*110
PER*HM*CHEMTREC-710399*TE*8004249300
W2*GATX*228481*4930040*RR*E**********T054
W3*979797*20200728*SULPHUACITRA*STOCKTON*CA
W4*THATCHER*UP*81*SALLAKCIT*UT
W5*UP*PSTKN*BNSF*PSTKN*CCT
LS*110
LH1*TK*1*UN1830**4930040****R*II
LH2*8*P***RQ
LH3*SULFURIC ACID*D
LFH*HZC*(SULFURIC ACID)
LE*110
PER*HM*CHEM-TREC CCN21327*TE*18004249300
W2*UP*92981*2042153*RR*L*84*********C114
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*4386*HAMER*ID
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*NATX*250323*2093343*RR*E**********T107
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*6161*BOARDMAN*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*645543*2093343*RR*E**********T107
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*6161*BOARDMAN*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*SSW*88104*3312253*RR*L*83*********F243
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*6930*RIVGATE*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W6*ND
W2*TTZX*856971*2421184*RR*L*108*********F483
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*72015*WILLAMINA*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W6*BN
W2*TTZX*864164*2421184*RR*L*101*********F483
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71712*DILLARD*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TBOX*663135*2499610*RR*L*89*********A606
W3*999999*20200723*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71670*MEDFORD*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TTZX*866528*2421170*RR*L*108*********F483
W3*999999*20200728*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71746*KIMWOOD*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TTZX*863637*2421184*RR*L*106*********F483
W3*999999*20200727*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*72015*WILLAMINA*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W6*BN
W2*TTZX*866386*2421184*RR*L*101*********F483
W3*999999*20200729*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71712*DILLARD*OR
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UP*96353*3312468*RR*L*102*********G719
W3*999999*20200726*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71*SEATTLE*WA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*SP*365172*3312468*RR*L*102*********E735
W3*999999*20200726*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71*SEATTLE*WA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*GNTX*290107*3312468*RR*L*96*********G719
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*71*SEATTLE*WA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TILX*292155*2899416*RR*L*98*********T108
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57726*GUYMON*OK
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TILX*281466*2899416*RR*L*99*********T108
W3*999999*20200723*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*28920*GLENVILLE*MN
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*GBRX*703876*2899416*RR*L*99*********T108
W3*999999*20200723*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*28920*GLENVILLE*MN
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UP*93416*0113216*RR*L*112*********C114
W3*999999*20200723*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*29360*HOPE*MN
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*CCLX*1959*2046115*RR*L*107*********T105
W3*999999*20200721*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57164*ARGO*IL
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*602066*2046115*RR*L*106*********T105
W3*999999*20200722*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57164*ARGO*IL
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*CCLX*1241*2046115*RR*L*99*********T104
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57164*ARGO*IL
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*CCLX*1996*2046115*RR*L*110*********T105
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57164*ARGO*IL
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*GATX*4486*2046115*RR*L*99*********T104
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57164*ARGO*IL
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*GATX*73119*2046115*RR*L*94*********T104
W3*999999*20200722*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*57164*ARGO*IL
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*12860*4930040*RR*E**********T054
W3*979797*20200724*SULPHUACITRA*STOCKTON*CA
W4*THATCHCONEVA*UP*9281*HENDERSON*NV
W5*UP*PSTKN*BNSF*PSTKN*CCT
LS*110
LH1*TK*1*UN1830**4930040****R*II
LH2*8*P***RQ
LH3*SULFURIC ACID*D
LFH*HZC*(SULFURIC ACID)
LE*110
PER*HM*CHEM-TREC CCN21327*TE*18004249300
W2*UTCX*50271*3291150*RR*L*91*********C214
W3*999999*20200721*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*54242*MCALESTER*OK
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*NATX*72430*2061625*RR*L*91*********T105
W3*999999*20200728*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*72936*BRAWLEY*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TTZX*861721*2499110*RR*L*109*********F483
W3*999999*20200724*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*52298*OAKDALE*LA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W6*ND
W2*BRCX*2003*2093343*RR*E**********T107
W3*999999*20200725*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*53134*FTWORTH*TX
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*SHPX*204500*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*645566*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*TILX*252266*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*664773*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*SHPX*204512*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*NATX*251437*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*645549*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
W2*UTLX*663050*2093343*RR*L*90*********T107
W3*999999*20200730*UPTRACKAGE*STOCKTON*CA
W4*UPTRACKAGE*UP*60094*STOCKTON*CA
W5*UP*PSTKN*BNSF*PSTKN*CCT
SE*254*10800001
GE*1*000001080
IEA*0001*975964991

Stedi is a registered trademark of Stedi, Inc. All names, logos, and brands of third parties listed on this page are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.