935 Measurement Significance Code
Code used to benchmark, qualify or further define a measurement value
- Type
- Identifier (ID)
- Length
- Min 2 / Max 2
- Codes
Code Description 01 Where Air = 1 02 Where Butyl Acetate = 1 03 Approximately 04 Equal to 05 Greater than or equal to 06 Greater than 07 Less than 08 Less than or equal to 09 Where H2O = 1 or Water = 1 10 Not equal to 11 Corrected to 60 Degrees Fahrenheit 12 Where Toluene = 1 13 Vapor in Air 14 Vapor in Other Than Air 15 Standard Temperature and Pressure 16 Conditions Other Than Standard Temperature and Pressure 17 In Ethyl Alcohol 18 In Ethyl Ether 19 In Water 20 At 1 Atmosphere Pressure 21 Where Ether = 1 22 Actual 23 Predicted 24 Air-dried Basis A condition representative of a partially dried sample25 As-received Basis A condition representative of a sample as it arrived at a laboratory, before any processing or conditioning26 Dry Basis A condition representative of no moisture in the sample27 Equilibrium Basis A condition representative of material in its natural state28 Moisture and Ash-Free Basis A condition representative of no moisture and no ash in the sample29 Oxidizing Atmosphere The presence of oxidizing gases during testing30 Reducing Atmosphere The presence of reducing gases during testing31 Calculated 32 Scaled Weight A weight that is taken from a scale rather than calculated34 Ratchet Highest previously attained value35 Saturated Vapor Measurement applies to the maximum amount of product material that can be held in vapor form without condensing36 Unconditional Measurement applies with no further conditions beyond those already specified37 Short-term Measurement applies only over the short-term specified38 Time-weighted Measurement signifies that the measurement for each event is weighted by the time duration of that event39 Corrected 40 Uncorrected 41 Off Peak 42 On Peak 43 Intermediate 44 Average Calculated Value was based on an average parameter or standard45 Per Gallon Calculated Value was based on per gallon parameter or standard46 Estimated 47 Minimum 49 Mist 50 Predominant 51 Total 52 Cost 53 Tenant 54 Owner 55 For Sale 56 Real Estate Owned or Corporate Owned 57 Boarded or Blocked Up 58 Planned 59 Completed 60 Sold 61 Rented 62 Current 63 Current List 64 Effective 65 List When Sold 66 Sales 67 Final List 68 As Is 69 As Repaired or Improved 70 Instantaneous 71 Low 72 Low to Good 73 Low to High 74 Low to Medium 75 Low to Moderate 76 Medium 77 Medium to Good 78 Medium to High 79 Moderate 80 Moderate to Good 81 Moderate to High 82 Moderate to Medium 83 Good 84 Good to High 85 High 86 Budgeted 87 Forecast 88 Adjusted 89 Allocated 90 Increasing 91 Stable 92 Declining 93 Previous 94 Potential 95 Modeled 96 Measured 97 Maximum 98 Regulated 99 Spring AA Summer On-peak AB Summer Mid-peak AC Summer Off-peak AD Summer Super On-peak AE Summer Super Off-peak AF Winter On-peak AG Winter Mid-peak AH Winter Off-peak AI Winter Super On-peak AJ Winter Super Off-peak AK Summer Day AL Summer Night AM Winter Day AN Winter Night AO Summer AP Winter AQ Day AR Night AS Peak-2 AT Peak-3 AU Peak-4 AV Shoulder AW Non Time Related Demand AX Fall AY Summer On Peak-2 Identifier for a tarriffed rate for metered service consumption and billingAZ Winter On Peak-2 Identifier for a tarriffed rate for metered service consumption and billingBA Probable Contamination BB Not Confirmed Value of the Result is Tentative Due to a Possible Identification ProblemBC Tentative Identification BD Failed BE Summer Mid Peak-2 Identifier for a tarriffed rate for metered service consumption and billingBF Winter Mid Peak-2 Identifier for a tarriffed rate for metered service consumption and billingZZ Mutually Defined
Sign up for free
Sign up for Stedi to instantly unlock documentation for X12, EDIFACT, and more.
Trusted by EDI professionals from leading companies
“Best EDI reference site online. I came across while researching a segment. I have been doing EDI since 1994.”
James Rossiter
EDI Professional