LTR Laboratory Test Results

To describe laboratory testing results, normal result ranges, or both

Position
Element
Name
Type
Requirement
Min
Max
Repeat
LTR-01
Code List Qualifier Code
Identifier (ID)
Mandatory
1
3
-
Code identifying a specific industry code list
LTR-02
Industry Code
String (AN)
Mandatory
1
30
-
Code indicating a code from a specific industry code list
LTR02 identifies the test performed.
LTR-03
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LTR03 and LTR06 are the readings for the test performed.
LTR-04
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LTR-05
Code List Qualifier Code
Identifier (ID)
Optional
1
3
-
Code identifying a specific industry code list
L0506: If LTR-05 is present, then LTR-06 is required
LTR-06
Industry Code
String (AN)
Conditional
1
30
-
Code indicating a code from a specific industry code list
LTR-07
Shipment Status Code
Identifier (ID)
Optional
1
2
-
Code indicating the status of a shipment
LTR-08
Range Minimum
Decimal number (R)
Conditional
1
20
-
The value specifying the minimum of the measurement range
LTR08 and LTR09 or both describe the expected normal ranges for the test performed. They may be used singly or together depending on the test.
LTR-09
Range Maximum
Decimal number (R)
Conditional
1
20
-
The value specifying the maximum of the measurement range
LTR-10
Gender Code
Identifier (ID)
Optional
1
1
-
Code indicating the sex of the individual
L100809: If LTR-10 is present, then at least one of LTR-08 or LTR-09 is required
LTR10 qualifies LTR08 and LTR09 or both if the expected ranges are gender dependent.
LTR-11
Range Minimum
Decimal number (R)
Optional
1
20
-
The value specifying the minimum of the measurement range
L110809: If LTR-11 is present, then at least one of LTR-08 or LTR-09 is required
LTR11 and LTR12 or both describe the minimum and maximum age ranges if the expected normal ranges (LTR08 and LTR09 or both) are age dependent.
LTR-12
Range Maximum
Decimal number (R)
Optional
1
20
-
The value specifying the maximum of the measurement range
L120809: If LTR-12 is present, then at least one of LTR-08 or LTR-09 is required

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.