V9 Event Detail

To specify information about a specific event

Position
Element
Name
Type
Requirement
Min
Max
Repeat
V9-01
Event Code
Identifier (ID)
Mandatory
3
3
-
Code identifying the event about which a report is made
V9-02
Event
String (AN)
Optional
1
25
-
Free-form description of event
V9-03
Date
Date (DT)
Optional
6
6
-
Date (YYMMDD)
V903 is the event date.
V9-04
Time
Time (TM)
Conditional
4
8
-
Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99)
V904 is the event time.
V9-05
City Name
String (AN)
Optional
2
30
-
Free-form text for city name
V9-06
State or Province Code
Identifier (ID)
Optional
2
2
-
Code (Standard State/Province) as defined by appropriate government agency
V9-07
Country Code
Identifier (ID)
Optional
2
3
-
Code identifying the country
V9-08
Status Reason Code
Identifier (ID)
Optional
3
3
-
Code indicating the status reason
V9-09
Standard Point Location Code
Identifier (ID)
Optional
6
9
-
Code (Standard Point Location) defined by NMFTA point development group as the official code assigned to a city or point (for ratemaking purposes) within a city
V9-10
Quantity
Decimal number (R)
Conditional
1
15
-
Numeric value of quantity
P1011: If either V9-10 or V9-11 is present, then the other is required
V910 is the length of the time delay expressed in hours.
V9-11
Train Delay Reason Code
String (AN)
Conditional
2
2
-
Code specifying reason for train delay
V9-12
Free-Form Message
String (AN)
Optional
1
30
-
Free-form information
V9-13
Time Code
Identifier (ID)
Optional
2
2
-
Code identifying the time. In accordance with International Standards Organization standard 8601, time can be specified by a + or - and an indication in hours in relation to Universal Time Coordinate (UTC) time; since + is a restricted character, + and - are substituted by P and M in the codes that follow
C1304: If V9-13 is present, then V9-04 is required
V913 reflects the time zone which the event time reflects.
V9-14
Quantity
Decimal number (R)
Optional
1
15
-
Numeric value of quantity
V914 is the quantity of the fuel in gallons.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.