LOC Location

To describe the location in space and time of the axis of an item relative to an origin axis euclidian geometry has been assumed with orthogonal axes; the sequence of axes has been chosen in the customary sequence of X, Y, and Z, however, it is possible to just use two-dimensional space rather than three-dimensional space

Position
Element
Name
Type
Requirement
Min
Max
Repeat
LOC-01
Reference Identification Qualifier
Identifier (ID)
Mandatory
2
3
-
Code qualifying the Reference Identification
LOC01 through LOC03 describe the item.
LOC-02
Reference Identification
String (AN)
Mandatory
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
LOC-03
Description
String (AN)
Optional
1
80
-
A free-form description to clarify the related data elements and their content
LOC-04
Reference Identification
String (AN)
Optional
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
LOC04 is a description of the positional reference point on the item.
LOC-05
Category
String (AN)
Optional
1
6
-
An alphanumeric identifier to represent the category to which the item belongs
LOC-06
Reference Identification Qualifier
Identifier (ID)
Conditional
2
3
-
Code qualifying the Reference Identification
P0607: If either LOC-06 or LOC-07 is present, then the other is required
LOC-07
Reference Identification
String (AN)
Conditional
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
LOC-08
Description
String (AN)
Optional
1
80
-
A free-form description to clarify the related data elements and their content
LOC05 through LOC08 describe the environment in which the item is placed.
LOC-09
Reference Identification
String (AN)
Optional
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
LOC09 is a description of the positional reference point in the environment. This is the origin of the original axes.
LOC-10
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LOC10 through LOC15 describe the translation in the three-dimensional space of the axes with respect to the original axes.
LOC10 is the principal X axis of the item.
LOC10 through LOC14 describe the principal XY plane of the item.
LOC-11
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LOC-12
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LOC-13
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LOC-14
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LOC-15
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LOC-16
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LOC16 is measured with respect to the XY plane around the X axis.
LOC-17
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LOC-18
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LOC18 is measured with respect to the YZ plane around the Y axis.
LOC-19
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LOC-20
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement
LOC20 is measured with respect to the ZX plane around the Z axis.
LOC-21
Composite Unit of Measure
Composite (composite)
Optional
01
Unit or Basis for Measurement Code
Identifier (ID)
Mandatory
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
02
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
03
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
05
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
06
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
07
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
08
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
09
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
10
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
11
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
12
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
13
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
14
Exponent
Decimal number (R)
Optional
1
15
-
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
15
Multiplier
Decimal number (R)
Optional
1
10
-
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
LOC-22
Reference Identification Qualifier
Identifier (ID)
Conditional
2
3
-
Code qualifying the Reference Identification
P2223: If either LOC-22 or LOC-23 is present, then the other is required
LOC-23
Reference Identification
String (AN)
Conditional
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
LOC-24
Description
String (AN)
Optional
1
80
-
A free-form description to clarify the related data elements and their content

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.