PSD Physical Sample Description
To define the physical sample parameters associated with a test resulting in discrete measurements
Position
Element
Name
Type
Requirement
Min
Max
Repeat
Code specifying the stage in the product development cycle at which the specimen was selected for testing
Code denoting the method of selecting the specimen
The number of samples collected
P0304: If either PSD-03 or PSD-04 is present, then the other is required
E0309: Only one of PSD-03 or PSD-09 may be present
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Power to which a unit is raised
If C001-02 is not used, its value is to be interpreted as 1.
Value to be used as a multiplier to obtain a new value
If C001-03 is not used, its value is to be interpreted as 1.
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Power to which a unit is raised
If C001-05 is not used, its value is to be interpreted as 1.
Value to be used as a multiplier to obtain a new value
If C001-06 is not used, its value is to be interpreted as 1.
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Power to which a unit is raised
If C001-08 is not used, its value is to be interpreted as 1.
Value to be used as a multiplier to obtain a new value
If C001-09 is not used, its value is to be interpreted as 1.
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Power to which a unit is raised
If C001-11 is not used, its value is to be interpreted as 1.
Value to be used as a multiplier to obtain a new value
If C001-12 is not used, its value is to be interpreted as 1.
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
Power to which a unit is raised
If C001-14 is not used, its value is to be interpreted as 1.
Value to be used as a multiplier to obtain a new value
If C001-15 is not used, its value is to be interpreted as 1.
Code describing the physical configuration or condition of the test specimen
Code specifying the direction in which the sample was collected or tested
Code specifying the position of an item such as the location, within a specimen, from which the sample was taken; the position of a coupon within an advertisement; etc
A free-form description to clarify the related data elements and their content
PSD08 can provide a more complete description of the physical sampling location.
To specify the sampling frequency in terms of a modulus of the Unit of Measure, e.g., every fifth bag, every 1.5 minutes