LTR Laboratory Test Results

To describe laboratory testing results, normal result ranges, or both

Position
Element
Name
Type
Requirement
Min
Max
Repeat
LTR-01
Code List Qualifier Code
Identifier (ID)
Mandatory
1
3
-
Code identifying a specific industry code list
LTR-02
Industry Code
String (AN)
Mandatory
1
20
-
Code indicating a code from a specific industry code list
LTR02 identifies the test performed.
LTR-03
Measurement Value
Decimal number (R)
Conditional
1
20
-
The value of the measurement.
LTR03 and LTR06 are the readings for the test performed.
LTR-04
Unit or Basis for Measurement Code
Identifier (ID)
Optional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
L0403: If LTR-04 is present, then LTR-03 is required
LTR04 qualifies the test reading in LTR03.
LTR-05
Code List Qualifier Code
Identifier (ID)
Optional
1
3
-
Code identifying a specific industry code list
L0506: If LTR-05 is present, then LTR-06 is required
LTR-06
Industry Code
String (AN)
Conditional
1
20
-
Code indicating a code from a specific industry code list
LTR-07
Status Code
Identifier (ID)
Optional
1
2
-
Code indicating the status of a shipment
LTR-08
Range Minimum
Decimal number (R)
Conditional
1
20
-
The value specifying the minimum of the measurement range.
LTR08 and LTR09 or both describe the expected normal ranges for the test performed. They may be used singly or together depending on the test.
LTR-09
Range Maximum
Decimal number (R)
Conditional
1
20
-
The value specifying the maximum of the measurement range.
LTR-10
Gender Code
Identifier (ID)
Optional
1
1
-
Code indicating the sex of the individual.
L100809: If LTR-10 is present, then at least one of LTR-08 or LTR-09 is required
LTR10 qualifies LTR08 and LTR09 or both if the expected ranges are gender dependent.
LTR-11
Range Minimum
Decimal number (R)
Optional
1
20
-
The value specifying the minimum of the measurement range.
L110809: If LTR-11 is present, then at least one of LTR-08 or LTR-09 is required
LTR11 and LTR12 or both describe the minimum and maximum age ranges if the expected normal ranges (LTR08 and LTR09 or both) are age dependent.
LTR-12
Range Maximum
Decimal number (R)
Optional
1
20
-
The value specifying the maximum of the measurement range.
L120809: If LTR-12 is present, then at least one of LTR-08 or LTR-09 is required

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.