PSD Physical sample description

To define the physical sample parameters associated with a test, resulting in discrete measurements.

Position
Element
Name
Type
Requirement
Min
Max
Repeat
010
Sample process status, coded
String (AN)
Conditional
1
3
-
Code specifying the stage in the product development cycle at which the specimen was selected for testing.
020
Sample selection method, coded
String (AN)
Conditional
1
3
-
Code denoting the method of selecting the test specimen.
030
Frequency details
Composite (composite)
Conditional
6071
010
Frequency qualifier
String (AN)
Mandatory
1
3
-
Indication of the application of a frequency.
020
Frequency value
Numeric (N)
Conditional
1
9
-
A value indicating a repetitive occurrence.
030
Measure unit qualifier
String (AN)
Conditional
1
3
-
Indication of the unit of measurement in which weight (mass), capacity, length, area, volume or other quantity is expressed.
See UN/ECE Recommendation 20.
040
Sample description, coded
String (AN)
Conditional
1
3
-
Code describing the state of the specimen.
050
Sample direction, coded
String (AN)
Conditional
1
3
-
Code specifying the direction in which the sample was taken.
060
Sample location details
Composite (composite)
Conditional
3237
010
Sample location, coded
String (AN)
Conditional
1
3
-
Code specifying the location, within the specimen, from which the sample was taken.
020
Sample location
String (AN)
Conditional
1
35
-
Free form description of the location within the specimen, from which the sample was taken.
070
Sample location details
Composite (composite)
Conditional
3237
010
Sample location, coded
String (AN)
Conditional
1
3
-
Code specifying the location, within the specimen, from which the sample was taken.
020
Sample location
String (AN)
Conditional
1
35
-
Free form description of the location within the specimen, from which the sample was taken.
080
Sample location details
Composite (composite)
Conditional
3237
010
Sample location, coded
String (AN)
Conditional
1
3
-
Code specifying the location, within the specimen, from which the sample was taken.
020
Sample location
String (AN)
Conditional
1
35
-
Free form description of the location within the specimen, from which the sample was taken.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.