S022 Status of the object

Identification of the length and if required the transfer status of the object.

Position
Element
Name
Type
Requirement
Min
Max
Repeat
010
Length of object in octets of bits
Numeric (N)
Mandatory
1
18
-
Count of the number of octets of bits in the object.
The count shall exclude the segment terminator of the preceding EDIFACT structured segment and the first character ('U') of the following EDIFACT structured segment.
020
Number of segments before object
Numeric (N)
Conditional
1
3
-
A count of the number of segments appearing between the UNO segment and the start of the object.
030
Sequence of transfers
Numeric (N)
Conditional
1
2
-
Number assigned by the sender indicating the transfer sequence of a message related to the same topic. The message could be an addition or a change to an earlier transfer related to the same topic.
The first message in the sequence shall be assigned as number 1.
040
First and last transfer
A
Conditional
1
1
-
Indication used for the first and last message in a sequence of messages related to the same topic.

Stedi is a registered trademark of Stedi, Inc. Stedi's EDI Reference is provided for marketing purposes and is free of charge. All names, logos, and brands of third parties listed on our site are trademarks of their respective owners (including “X12”, which is a trademark of X12 Incorporated). Stedi, Inc. and its products and services are not endorsed by, sponsored by, or affiliated with these third parties. Our use of these names, logos, and brands is for identification purposes only, and does not imply any such endorsement, sponsorship, or affiliation.